Product name:Low Intensity LED Steady Type or Flashing Type(E27 type)

Input voltage:85-265VAC, 50/60 Hz;12VDC; 24VDC;30-60VDC;

Effective Intensity: >50 Candela

LED Lifespan:100,000 Hours

Materials:Lens-PC; Body- Aluminum

Optional LED Color

  • baise6
  • baise6
  • baise6
  • baise6
  • baise6
  • DL32D (1)
  • DL32D (2)
  • DL32D (3)
  • DL32D-7_副本_副本

Downloads

Overview

Features

Specifications

Advantages

Installation and operation

Video

LANSING DL50DE low intensity dual obstruction light is composed of two DL50SE single obstruction lights and a compartment for its control board. It has two operation modes: “Service+Standby” and “Service+Service”. DL50DE dual aircraft warning light is compliant to ICAO obstacle light low intensity type C.

Service+Standby: one DL50SE single light (Service light) operates normally. Once Service light fails, DL50DE dual light automatically transfers to Standby light for continuous operation Service+Service: two DL50SE single lights work simultaneously, and either failure does not affect the other normal operation.

With a G3/4” universal threaded hub on the bottom, DL50DE twin aircraft warning light can be mounted on a conduit or with Lansing brackets designed for towers and buildings. There is a terminal block on the control board in the intermediate compartment, for connecting to power and alarm.

In most cases, DL50DE double obstruction lights are installed on top of structures less than 45m. In some cases, multiple DL50DE double lights are used in one or more horizontal levels for marking a structure’s outline with medium intensity obstruction lights.


  • Previous:
  • Next:

  • • Based on Led Technologies with E27 Type led Bulb

    • Available for both AC and DC conditions

    • Can be operated in steady-burning or flashing mode

    • Lens made from durable, UV-stabilized LEXAN polycarbonate

    • Aluminum base with powder painted, corrosion-resistant

    • G3/4 threaded bottom entry for easy mounting

    • All hardware of obstruction lights are made of corrosion resistant metals

    • Bird spikes for protection against droppings

    • With NVG(Night Vision Goggles), this should be customized(optional)

    • Photocell option for automatic activation at night

    • No regular maintenance

    • Uses 96% less power than an incandescent light

    • With surge protection up to 2KV

    • Excellent shock and vibration resistant

    • No RF Radiations, EMC Compliant

    • Reversed Polarity Protected(DC Type)

    • Corrosion resistant lamp & housing-suitable for off-shore use

    • Self-contained wiring compartment-eliminates additional box

    • Flashing rate adjustable

    • Both NO dry alarm contacts are available, and it will give an alarm in case of power and light failure(optional)

    • Available both in single and double type

    • 2 years warranty

    Item DL50DESS DL50DEST
    06b89d1435b0c2ef7908cfd072a3b52 1e8c6d2e761f7b4d057ae7651a2c01a
    ELECTRICAL CHARACTERISTIC Effective Intensity >50 Candela
    Vertical Divergence 10 Degree
    Horizontal out-put 360 Degree
    LED Color Red, yellow, white, green or blue
    LED Lifespan 100,000 Hours
    OPERATION Woke mode Flashing
    Operation mode Service+Service Service+Standby
    Flash Pattern Flashing: 20/30/40/60FPM;Default: 40FPM;Steady burning
    Flash duration 670ms
    Photocell sensitivity 70-100 Lux
    Alarm type: NO & NC, dry contact relay
    POWER SUPPLY Input voltage 85-265VAC, 50/60 Hz;12VDC; 24VDC;30-60VDC;
    Power consumption 10W (Steady burning)
    MECHANICAL STRUCTURE Lens Polycarbonate, UV Stabilize 
    Body Die-casting Aluminum
    IP Ingress IP65
    Weight 3KG
    Operating Temperature  -40℃ ~ +55℃
    Storage Temperature  -40℃ ~ +70℃
    Wire Connection mode Threaded 3/4” bottom entry
    Relative humidity 0-95% RH non-condensing
    Wind speed Up to 150mph(240kph)
    OTHERS Warranty 2 years
    Optional Flashing pattern(20–60FPM)
    Built-in photocell
    NO dry contact relay

    ee9e09aadbe0384bf69705fee83bf1c

    ① Secure the light on a smooth surface which has enough strength, if there is no mounting surface, we can customize special mounting bracket as request.

    ② When installation, please stay away the nearby light source, at the same time, ensure the photocell do not cover by the near object if photocell is available.

    ③ Make sure the power supply can match the rated power of light before connecting.

    ④ Unfasten the screws between housing and light base and open the housing, then the terminals appear.

    ⑤ According to the mark on the wiring label of the lamp lead wire, connect the power cable and the alarm wire correctly. Please pay attention to the polarity of the positive and negative poles for the DC voltage.

    ⑥ After finishing the connection, fasten the housing to the light body tightly.

    ⑦ Check whether the power cables are connected correctly before power on.

    ⑧ The flash rate 40FPM by default. lf you need to customize, please inform the lamp manufacturer before purchasing.

    Note:

    A. If the lamp has built in photocell, remember to cover the photocell with a black cloth if you test the lamp in the daytime, then the lamp will start to work.

    B. If the lamp has GPS function, the fixture needs to be kept in an open area outdoor and the GPS function will work after 5-10 minutes.