CBL04F Control Box


  • Min.Order Quantity: 1 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Port: Shanghai
  • Payment Terms: L/C,D/A,D/P,T/T,Westernunion, Paypal
  • Product Detail

    Main functions and features

    Specification

    Installation dimension

    STANDARD

    The CBL04F is an obstruction lighting Control box designed for controlling and monitoring Lansing LED low intensity and medium intensity aviation obstruction lights. Incorporated an AC/DC power converter, CBL04B allows users to input AC voltage (85-265VAC) and converts to 48VDC/24VDC/12VDC for electrical safety works. The user-friendly interface is intuitive for users to monitor operation status and easily configure functions and for monitor lighting operation system for the following failures: burned out lamp, photocell, power failure. & flashing rate control.

    There are eight light outputs (max. 1A load/output). Practically, for example, for input voltage 48VDC, each output  connects one ZG2K or F864 medium intensity light, or up to Seven DL32/DL100 low intensity lights.

    With a Form C dry alarm relay (NO&NC), the control box is capable of transmitting the obstruction lighting system’s failure to users’ alarm devices, when light failure, power-off or photocell failure.

    A PT01 photocell is used for automatically switching on and off the obstruction lighting system from dusk to dawn.

    Bypass switch on interface panel allows users to bypass the photocell for permanently lightening or testing.

    DIN-rail terminal blocks save wiring time and enhance wiring safety. A 2P circuit breaker is effective in protecting the control box from overload. A surge protector (reach 20KV) enhances protection against voltage fluctuation and lightning strikes.


  • Previous:
  • Next:

  •  Control several light flashing synchronously

    • LED indicators for lights, power and photocell.

    • Up to four light outputs, 1-5 selectable upon actual application.

    • Each light output load maximum 1A

    • Steady/Flashing adjustable

    • Din-rail terminal blocks save wiring time and enhance wiring safety.

    • Bypass switch—can switch ON/OFF the light when the photocell is not available

    • Up to 5 dry contact relays(NO&NC) for eight light outputs, power and photocell

    • Circuit breaker against overload and short-circuit

    • External photocell with prewired shielded cable easy for maintain, in case of photocell failure, the control will give an alarm

    • Surge protector(up to 20KV) against voltage fluctuation and lighting strikes.

    • ”Service+Service”/”Service+Standby” adjustable when double lights used.

    • With lock, to prevent stolen when outside.

    • Automatic switching on and off of lighting.

    • Additionally installed switch S191B6 enabling service switching on lighting during the day.

    • Signaling voltage presence on lamp Installation size(mm)s.

    • Providing surge protection for lamps and switch gear circuits.

    • Switching power supply to another phase in the event of a power outage on one of the three phases.

    Input voltage AC85-265V Output voltage DC48V
    Number of Light output way Alarm output 4 channels
    On/off level 70~100Lux Flashing rate 20~60times/mins(Adjustable)
    Surge Protection 2KV Alarm NO&NC,Dry contact alarm
    Operating temperature -30˚C ~ +70˚C IP Protection IP65
    Humidity 10% ~ 95% Weight 6kg
    Material Die casting aluminum Mounting Wall mounting or U-bolt mounting
    Steady burning and flashing mode available

    • ICAO Annex 14, 4th Edition, July 2004
    • FAA AC No. 150/5345-43F, 2006
    •