CBL02A Obstruction Light Monitoring Controller

Short Description:

Input&output voltage: 48VDC

Number of Light output: 2*contact relay for lights, power and photocell

Photocell sensitivity: 70~100Lux

Photocell bypass: Auto/Manual adjustable

Alarm type: NO&NC,Dry contact alarm

Materials: Aluminum alloy

IP protection: IP65

  • DL32D-2
  • TY50S LED (1)
  • DL32D-7_副本_副本

Downloads

Overview

Features

Specifications

Advantages

Mounting dimension

The CBL02A is an obstruction lighting Control box designed for controlling and monitoring Lansing LED low intensity and medium intensity aviation obstruction lights. The user-friendly interface is intuitive for users to monitor operation status and easily configure functions and for monitor lighting operation system for the following failures: burned out lamp, power failure. & flashing rate control.

There are two light outputs (max. 1A load/output). Practically, for example,it can connect two single DL32S low intensity aviation lights at the same time, or 1 dual DL32D aviation lights.

With a Form C dry alarm relay (NO&NC), the control box is capable of transmitting the obstruction lighting system’s failure to users’alarm devices, when light failure or power-off failure.

A external PT01 photocell is used for automatically switching on and off the obstruction lighting system from dusk to dawn, or we can put an internal photocell for easy installation if requires.

Bypass switch on interface panel allows users to bypass the photocell for permanently lightening or testing.

CBL02A outdoor controller covered by an aluminum enclosure and assembled with cable glands, is a perfect IP65 model for harsh environment use.


  • Previous:
  • Next:

  •  On/off Main Power Supply

     Control two lights flashing synchronously

     LED indicators for light, power and photocell

    “Service+Service”/”Service+Standby” adjustable when double lights used

     Two light-outputs, 1-2 selectable upon actual application

     Each light output load maximum 1A

     Steady and Flashing adjustable

     External photocell with prewired shielded cable, easy to maintain

     Photocell bypass switch—can switch ON/OFF the light when the photocell is not available

     One dry contact relay (From C, NO&NC) for alarm output of lights and power

    • Circuit breaker against overload and short-circuit

    • Surge protector(up to 2KV) against voltage fluctuation and lighting strikes.

    Item CBL02A
    POWER SUPPLY Input voltage 48V DC
    Max.Load/Output 1A
    Flash Rate Steady/Flashing(20FPM), adjustable
    Photocell sensitivity 70-100 Lux
    Photocell bypass Auto/Manual adjustable
    Alarm type NO & NC, dry contact relay
    Numbers of Alarm Output 2*contact relay for lights, power and photocell
    MECHANICAL STRUCTURE Enclosure Type Outdoor
    Enclosure Material Aluminum alloy
    Protection IP65
    Net Weight 1.2kg
    Dimension (H*W*Depth) 188mm*120mm*78mm
    Operation Temperature -30˚C ~ +70˚C
    Operation Humidity 0-95% RH non-condensing
    Mounting Wall mounting or U-bolt mounting

    CBL02A

    Mounting-dimensionmm

    Mounting dimension(mm)